Z SERIES · LOW-PROFILE ZA CONFIGURATION

Z Series 2–12 kW Low-Profile High Voltage PTC Coolant Heater

A 90 mm-high liquid-heater package for construction machinery and electric light-duty truck thermal systems, with electric-bus programs evaluated project by project.

Confirm the released power range, ZA connector interfaces, Ø20 mm coolant circuit and machine-level validation scope before quotation or production use.

High Voltage Coolant Heater
2–12 kW
Rated power range
243 × 165 × 90 mm

Published package reference

Ø20 mm

Published coolant-port reference

2

Priority vehicle groups in title artwork

SELECTION LOGIC

Choose the Z Series for Low-Height Installation

The Z Series should answer low-profile packaging and lower-power off-highway searches before repeating generic PTC-heater features.

90 mm

Low Package Height

Evaluate the flat enclosure where vertical clearance is restricted.

2–12 kW Rated Power

Lower-Power Thermal Duty

The Z Series technical specification lists an 2–12 kW rated power range. Confirm the required output for the selected operating conditions.
ZA

Housing-Mounted Interfaces

Confirm both electrical connectors and their mating parts as part of the heater release.

High Voltage Coolant Heater
APPLICATION EVALUATION

Prioritize Construction Machinery and Light-Duty Trucks

The Z-Series title artwork specifically names construction machinery and light-duty trucks. The supplied application artwork also shows electric buses, so bus use remains a project-specific engineering evaluation.

High Voltage Coolant Heater
MECHANICAL PACKAGE

Validate the 90 mm-High Heater Envelope

The low-profile enclosure can solve vertical-clearance constraints while the two same-side coolant connections and electrical interfaces still require service space.

INTERFACE RELEASE

Confirm Both ZA Electrical Interfaces

The source-folder label associates this ZA configuration with high- and low-voltage Amphenol connectors, and the orange housing carries visible Amphenol marking. Exact series, part numbers, keying and mating definitions are not published.

High Voltage Coolant Heater
TECHNICAL BASELINE

Z-Series Low-Profile Coolant-Heater Specifications

Use supplied values for early engineering review and released project documents for final limits, tolerances and evidence.

Rated power

2–12 kW series range; confirm the ordered configuration and rating conditions

Rated voltage

Customizable — exact nominal voltage to confirm

Operating voltage

200–800 V DC operating range

Package reference

243 × 165 × 90 mm

Coolant ports

Ø20 mm reference

Insulation resistance

≥100 MΩ at DC 1000 V, high-voltage section

Dielectric strength

≥1200 V, ceramic heating element

Peak current

≤1.5 × rated current

Ingress protection

IP67 listed; report and configuration applicability to confirm

Storage / operating temperature

−40 °C to +85 °C / −40 °C to +85 °C

Communication

CAN bus with enable control

Control

PID, fault self-diagnosis and automatic power limiting

The supplied Z-series parameter table lists a weight of 3.45 kg. Confirm the installation mass, electrical interfaces and released drawing for the selected configuration. Certification and test evidence must identify the applicable product and revision.

PRODUCT VIEWS

Inspect the Housing, Mounts, Ports and Connectors

Use supplied views for early screening and the released drawing for production packaging.

High Voltage Coolant Heater
High Voltage Coolant Heater
High Voltage Coolant Heater
High Voltage Coolant Heater
CONTROL & PROTECTION

Convert Listed Functions into a Machine Test Matrix

CAN, PID and protection names support screening; release needs thresholds, reactions, feedback, recovery and revision traceability.

01

Command

CAN requests, enable logic, wake-up, shutdown and restart behavior.

02

Regulation

PID ownership, power demand, measured values and automatic limiting.

03

Protection

Voltage, current, short-circuit and overtemperature trigger conditions.

04

Evidence

Fault injection, derating, recovery, diagnostics and controlled software revision.

High Voltage Coolant Heater
QUALIFICATION EVIDENCE

Request Records for the Exact Z-Series Configuration

Factory and certificate-display artwork can support supplier review, but product approval should rely on controlled records matching the exact heater, connectors, software and validation scope.

FAQ

Z-Series Low-Profile Coolant-Heater Questions

Answers separate supplied facts from details requiring a controlled project release.


The Z Series technical specification lists a rated power range of 2–12 kW. Confirm the final electrical configuration and required output for your project.
The Z Series technical specification lists a rated power range of 2–12 kW. Confirm the final electrical configuration and required output for your project

The supplied technical panel lists 200–800 V and describes rated voltage as customizable. Confirm nominal voltage, minimum and maximum DC voltage and transient requirements for the exact Z-Series configuration.

The product-display artwork lists 243 × 165 × 90 mm and marks Ø20 mm coolant ports. Use those figures as an early package reference and request the released drawing for tolerances, mounting and hose engagement.

The source-folder label associates this ZA configuration with high- and low-voltage Amphenol connectors, and the orange housing is visibly marked in the supplied product imagery. The exact series, part numbers, keying, pinout and mating components are not published and must be confirmed.

The supplied technical panel lists CAN bus with enable control, PID control, fault self-diagnosis, automatic power limiting, and overvoltage, undervoltage, overcurrent, short-circuit and overtemperature protection. Thresholds and response behavior require project documentation.

The supplied artwork shows construction machinery, electric trucks and electric buses. The Z-Series title artwork specifically prioritizes construction machinery and light-duty trucks; suitability depends on heat duty, voltage, coolant circuit, packaging, vibration, contamination and validation requirements.

Send the machine or vehicle type, voltage window, required heat output, coolant and flow data, temperature and pressure limits, installation envelope, connector requirements, CAN requirements, validation scope, sample timing and forecast volume.

PROJECT BRIEF

Send the Inputs Needed for a Z-Series Recommendation

A useful response depends on thermal duty, package space, exact interfaces and release evidence—not only a target power number.

01

Machine & Duty

Construction machine, truck or bus; operating profile and ambient conditions.

02

Thermal Loop

Heat duty, coolant, flow, inlet/outlet temperatures, pressure limits and target time.

03

Electrical

Nominal/min/max voltage, connector requirements, grounding, CAN and enable logic.

04

Program

Package envelope, sample timing, validation scope, SOP and forecast volume.